  1.                          SECTION 09843
  2.  
  3.                CORK-FACED ACOUSTICAL WALL PANELS
  4. NOTE ** This section is based on the products of the
  5.         Homasote Company, which is located at:
  6. NOTE **    P.O. Box 7240
  7. NOTE **    West Trenton, NJ  08628-0240
  8. NOTE **    Tel:  (609) 883-3300
  9. NOTE **    Fax:  (609) 530-1584
  10. NOTE **    Internet address:  http://www.homasote.com
  11. NOTE **    For local rep contact:  Sweet's Buyline 1-800-
  12.         892-1165 (#0878)
  13. NOTE ** The Homasote Company manufactures various products
  14.         for the building industry.  This section covers
  15.         only a part of their product line:  "Nova" cork-
  16.         faced acoustical wall panels.  Nova cork paneling
  17.         is a completely finished structural panel requiring
  18.         no on-site surface treatment.  Panels in 4 by 8
  19.         sizes are fire rated Class B and are available
  20.         Class A.  Cut to size panels are Class B fire
  21.         rated.
  22. NOTE **
  23. NOTE ** See their other sections for wood roof decking,
  24.         fiberboard underlayment, acoustical barriers (fire-
  25.         rated and non-rated), and fabric-covered acoustical
  26.         wall panels.
  27. NOTE **
  28. NOTE ** SECTION 09843 - CORK-FACED ACOUSTICAL WALL PANELS,
  29.         Copyright 1998, The Architect's Catalog, Inc.
  30.  
  31. PART 1  GENERAL
  32.  
  33. 1.1 SECTION INCLUDES
  34. NOTE ** Select paragraphs below applicable to project.
  35.  
  36.     A.  Class A cork-faced acoustical wall panels manufactured
  37.         from recycled wood fiber material.
  38.  
  39.     B.  Class B cork-faced acoustical wall panels manufactured
  40.         from recycled wood fiber material.
  41.  
  42. 1.2 RELATED SECTIONS
  43. NOTE ** Delete sections below not relevant to this project;
  44.         add others as required.
  45.  
  46.     A.  Section 06100 - Rough Carpentry.
  47.  
  48.     B.  Section 09110 - Non-Load-Bearing Wall Framing.
  49.  
  50.     C.  Section 09250 - Gypsum Board.
  51.  
  52.     D.  Section _____ - _________________________.
  53.  
  54. 1.3 REFERENCES
  55. NOTE ** Delete references from the list below that are not
  56.         actually required by the text of the edited
  57.         section; add others as required.
  58.  
  59.     A.  ASTM E 84 - Test Method for Surface Burning
  60.         Characteristics of Building Materials.
  61.  
  62.     B.  ____________________________________.
  63.  
  64. 1.4 SUBMITTALS
  65.  
  66.     A.  Submit under provisions of Section 01300.
  67.  
  68.     B.  Product Data:  Manufacturer's catalog data, detail
  69.         sheets, and specifications.
  70.  
  71.     C.  Samples:  Two samples of manufacturer's cork applied to
  72.         substrate material indicating range of color; 7 by 7
  73.         inches (180 by 180 mm).
  74.  
  75.     D.  Quality Assurance/Control Submittals:
  76.         1.  Manufacturer's installation instructions.
  77.  
  78.     E.  Closeout Submittals:  Maintenance and cleaning
  79.         instructions.
  80.  
  81. 1.5 QUALITY ASSURANCE
  82.  
  83.     A.  Manufacturer's Qualifications:
  84.         1.  Minimum 10 years experience in producing acoustical
  85.             panels of the type specified herein.
  86.  
  87. 1.6 DELIVERY, STORAGE, AND HANDLING
  88.  
  89.     A.  Deliver materials in manufacturer's original packages.
  90.  
  91.     B.  Inspect the materials upon delivery to assure that
  92.         specified products have been received.
  93.  
  94.     C.  Report damaged material immediately to the delivering
  95.         carrier and note such damage on the carrier's freight
  96.         bill of lading.
  97.  
  98.     D.  Store materials in a dry place, indoors, or on raised
  99.         platform protected from weather damage.
  100.  
  101. 1.7 PROJECT CONDITIONS
  102.  
  103.     A.  Environmental Requirements:  For 24 hours before, during,
  104.         and continually after installation, maintain temperature
  105.         and humidity conditions that will approximate interior
  106.         conditions following building occupancy.
  107.  
  108.  
  109. PART 2  PRODUCTS
  110.  
  111. 2.1 MANUFACTURERS
  112.  
  113.     A.  Acceptable Manufacturer:  Homasote Company, P.O. Box
  114.         7240, West Trenton, NJ 08628-0240; ASD. Tel: (609) 883-
  115.         3300, Fax: (609) 530-1584, Internet address:
  116.         http://www.homasote.com; For local rep contact:  Sweet's
  117.         Buyline 1-800-892-1165 (#0878).
  118.  
  119.     B.  Requests for substitutions will be considered in
  120.         accordance with provisions of Section 01600.
  121. NOTE ** Delete paragraph above or below; coordinate with
  122.         Division 1 requirements.
  123.  
  124.     C.  Substitutions:   Not permitted.
  125.  
  126.     D.  Provide all cork-faced acoustical wall panels from a
  127.         single manufacturer.
  128.  
  129. 2.2 MATERIALS
  130. NOTE ** Nominal size of panels is 4 by 8 feet (1.219 by
  131.         2.438 m).  Actual size is 47-3/16 by 95-7/8 inches
  132.         (1.198 by 2.435 m).
  133.  
  134.     A.  Class A Cork Panels:  Homasote Nova Cork Panels.
  135.         1.  Substrate:  NCFR(R) fiberboard manufactured from 100
  136.             percent recycled wood fiber material; physical
  137.             properties as follows:
  138.             a.  Thickness:  1/2 inch (13 mm).
  139.             b.  Density:  34-40 pcf (545-640 kg/cubic m).
  140.             c.  Water Absorption by volume (2 hour immersion):  5
  141.                 percent maximum.
  142.             d.  Expansion, 50 to 90 percent relative humidity:
  143.                 0.30 percent.
  144.             e.  R-value:  0.85 (0.015).
  145.             f.  NRC:  0.20.
  146.             g.  Flame Spread (cork on one face):  25, per ASTM E
  147.                 84.
  148.             h.  Smoke Developed (cork on one face):  20, per ASTM
  149.                 E 84.
  150.             i.  Fuel Contributed (cork on one face):  10.
  151.             j.  Classification:  Class A, per NFPA.
  152.  
  153.     B.  Class B Cork Panels:  Homasote Nova Cork Panels.
  154.         1.  Substrate:  "440" fiberboard manufactured from 100
  155.             percent recycled wood fiber material; physical
  156.             properties as follows:
  157.             a.  Thickness:  1/2 inch (13 mm).
  158.             b.  Density:  24-26 pcf (385-415 kg/cubic m).
  159.             c.  Water Absorption by volume (2 hour immersion):  5
  160.                 percent maximum.
  161.             d.  Conditioned Moisture Content:  15 percent
  162.                 maximum.
  163.             e.  Expansion, 50 to 90 percent relative humidity:
  164.                 0.25 percent.
  165.             f.  R-value:  1.11 (0.19).
  166.             g.  NRC:  0.20.
  167.             h.  Flame Spread (cork on one face):  70, per ASTM E
  168.                 84.
  169.             i.  Smoke Developed (cork on one face):  40, per ASTM
  170.                 E 84.
  171.             j.  Fuel Contributed (cork on one face):  50.
  172.             k.  Classification:  Class B, per NFPA.
  173.  
  174.     C.  Cork Surface:  Natural color, virgin cork.
  175. NOTE ** Select fabrication to suit the project from the two
  176.         paragraphs following.
  177.  
  178.     D.  Fabrication:  Laminate cork to one side of substrate with
  179.         continuous uniform coat of waterproof adhesive.
  180.         1.  Edge Detail:  All edges square.
  181.  
  182.     E.  Fabrication:  Laminate cork to both sides of substrate
  183.         with continuous uniform coat of waterproof adhesive.
  184. NOTE ** Beveled edges are available on individual panels up
  185.         to 36 by 48 inches.  Panels 48 by 96 inches are
  186.         available beveled on long edges only.  Select edge
  187.         detail to suit the project from the two
  188.         subparagraphs below.
  189.         1.  Edge Detail:  Beveled edges, one face only.
  190.         2.  Edge Detail:  Long edges  beveled, one face only.
  191.  
  192. 2.3 ACCESSORIES
  193. NOTE ** Installation accessories are dependent on
  194.         substrates and installation methods as recommended
  195.         by the manufacturer; select from the following
  196.         paragraphs accordingly.
  197.  
  198.     A.  Metal Frame Clips:  Manufacturer's standard clip for
  199.         securing panels to framing.
  200.  
  201.     B.  Adhesive:  APA approved panel adhesive.
  202.  
  203.     C.  Adhesive:  APA AFG-01 subfloor adhesive.
  204.  
  205.     D.  Nails:  Color coordinated paneling nails, length as
  206.         required to penetrate wood framing 3/4 inch (19 mm)
  207.         minimum.
  208.  
  209.     E.  Nails:  Finishing nails, length as required to penetrate
  210.         wood framing 3/4 inch (19 mm) minimum.
  211.  
  212.     F.  Screws:
  213.         1.  Wood Framing:  Coarse thread drywall type wood screw,
  214.             length as required to penetrate framing 3/4 inch (19
  215.             mm) minimum.
  216.         2.  Metal Framing:  22-25 gage, drywall type steel screw.
  217.         3.  Metal Framing:  20 gage or heavier, self-tapping
  218.             drywall type steel screw.
  219.  
  220.  
  221. PART 3  EXECUTION
  222.  
  223. 3.1 EXAMINATION
  224.  
  225.     A.  Examine substrates upon which work will be installed.
  226.  
  227.     B.  Verify framing member spacing complies with
  228.         manufacturer's requirements depending on substrates and
  229.         installation methods.
  230.  
  231.     C.  Verify environmental conditions are, and will continue to
  232.         be, maintained in accordance with manufacturer's
  233.         recommendations.
  234.  
  235.     D.  Coordinate with responsible entity to perform corrective
  236.         work on unsatisfactory substrates or conditions.
  237.  
  238.     E.  Starting work by installer is acceptance of substrate and
  239.         environmental conditions.
  240.  
  241. 3.2 PREPARATION
  242.  
  243.     A.  Follow manufacturer's instructions for allowing panels to
  244.         be exposed to environmental temperature and humidity
  245.         conditions for not less than 24 hours before start of
  246.         installation.
  247.  
  248. 3.3 INSTALLATION
  249. NOTE ** Homasote specifies framing at 16 inches (400 mm)
  250.         o.c. for all installation methods except over
  251.         finished walls; panel edges and ends are required
  252.         to align with framing members or be blocked for all
  253.         methods.  Verify that appropriate framing section
  254.         or drawing notes comply.  Special framing may be
  255.         required if panel joint layout is defined.
  256. NOTE **
  257. NOTE ** Furring for masonry or concrete walls can be one-
  258.         by's (19 mm) wood or standard hat-shaped metal
  259.         furring channels.  Specify furring in the
  260.         appropriate wood or metal framing section.
  261.  
  262.     A.  Follow manufacturer's instructions for cutting and
  263.         installation of panels:
  264. NOTE ** Installation is dependent on substrates; select
  265.         from the following subparagraphs accordingly,
  266.         deleting those not required for the project.
  267.         1.  Wood Framed Walls, Method No. 1, (using framing
  268.             clips).
  269.         2.  Wood Framed Walls, Method No. 2, (using adhesive).
  270.         3.  Metal Framed Walls.
  271.         4.  Wood or Metal Furring over masonry or concrete walls.
  272.         5.  Finished Walls (walls with continuous substrate in
  273.             place).
  274.  
  275. 3.4 CLEANING
  276.  
  277.     A.  Follow manufacturer's instructions for cleaning panels
  278.         soiled during installation.
  279.  
  280.     B.  Replace panels that cannot be cleaned to "as new"
  281.         condition.
  282.  